Basic Info
Model NO. BYM1
Poles Number 3p/4p
Type Circuit Breaker
Function Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification ISO9001-2000, CE, CCC
Rated Operation Voltage 400/415V
Standard IEC60947-2
Rated Insulation Voltage 800V
Transport Package Carton
Trademark OEM ODM
Origin China
HS Code 853620000
Production Capacity 40000
Product Description

Ninewan MCCB Breaker 3p 63A 80A 125A AC400V 50Hz 3 Phase Moulded Case Circuit Breaker 4 Pole MCCB

Product Description

Standard:
circuit breaker and auxiliaries comply with the following international standard:
1.IEC/EN 60947-1
Low-voltage switchgear and controlgear-part 1: General rules;
2.IEC/EN 60947-2
Low-voltage switchgear and controlgear-part 2: Circuit breakers;

MCCB(Standard use environment for MCCB)
1. Ambient temperature: Within the range of -5ºC--+55ºC(However, when the temperature exceed 40ºC,it should be considered to reduce the capacity to use);
2. Relative humidity: Within the range of 45%--85%;
3. Altitude: 2000m or less(However, if it exceeds 1000m, atmosphere correction through humidity test and withstand voltage test can be considered);
4. Atmosphere where excessive steam, oil steam, smoke, dust, salt and other corrosive materials do not exist;

Classification:
According to the poles: 2-poles, 3-poles
According to the rated current: Fix type

Product Parameters

Thermal-Magnetic fixed type Circuit Breakers
ModelXHM1-125
Breaking Capacity CodeLMH
Rated Current of Frame size- Inm (A)160A
Rated Current-In(40,50 or 55ºC) (A)10- 12,5-16-20 - 25 - 32 - 40 - 50 - 63 - 80 - 100 -125 - 160(150)A
Rated İnsulation Voltage -Ui(a.c.) 50-60Hz (V)800V
Rated operation Voltage -Ue(a.c.) 50-60Hz (V)400/415V
Number of Pole 34
Rated ultimate short Circuit breaking Capacity kA Icu AC400V/50Hz O-CO (KA)253550
Rated service short Circuit breaking Capacity kA Ics AC400V/50Hz O-CO-CO (KA)12.52237.5
Rated short-circuit breaking capacity Icm(peak)/cos ф AC400V/50HZ O-CO (KA)41/0.373.5/0.25110/0.25
Rated impulse withstand Voltage -Uimp (V)8000
Dielectric Propery (V) 3000
lonization distance (mm)≤50/0
Endurance Total Cycles 8000
Electrical Life 1000
Mechanical Life 7000
Over Current trip Thermal and Magnetic release fix type
Category (EN 14048.2/IEC 60947-2)Main circuit A/0
Auxiliary circuit AC-15
Under Voltage Release
Shunt Release
Auxiliary Contact
Alarm Contact
Auxiliary Contact and Alarm Contact
Handle Operation Mechanism
Electrical Operastion Mechanism
Terminal cover
Phase seperator
Extention Handle -
W (mm)3P92
4P122
L (mm)3P150
4P150
H (mm)3P68
4P86
WeightFixed version 3P/4P1.2/1.6
Plug-in version 3P/4P1.4/1.8
Draw out version 3P/4P-

Detailed Photos

Ninewan MCCB Breaker 3p 63A 80A 125A AC400V 50Hz 3 Phase Moulded Case Circuit Breaker 4 Pole MCCB

Ninewan MCCB Breaker 3p 63A 80A 125A AC400V 50Hz 3 Phase Moulded Case Circuit Breaker 4 Pole MCCB

Ninewan MCCB Breaker 3p 63A 80A 125A AC400V 50Hz 3 Phase Moulded Case Circuit Breaker 4 Pole MCCB

Ninewan MCCB Breaker 3p 63A 80A 125A AC400V 50Hz 3 Phase Moulded Case Circuit Breaker 4 Pole MCCB

Ninewan MCCB Breaker 3p 63A 80A 125A AC400V 50Hz 3 Phase Moulded Case Circuit Breaker 4 Pole MCCB


Send inquiry