Ep Hipot Electric Series Resonance AC Withstand Tester High Voltage Resonant Test System for Cable
EP Hipot Electric Series Resonance AC Withstand tester high voltage Resonant test system for cableEPCZ Series Variable F;
Basic Info
Model NO. | EPCZ Series |
Customized | Customized |
Color | Orange |
Output Voltage | Customized |
Capacitance | Customized |
Output Frequency | 30 -300Hz |
Working Duration | Can Be Customized |
The System Is Consisted by | Variable Frequency Power Supply |
Resonant Voltage Waveform | Sine Wave, Waveform Distortion Rate <1.0% |
Maximum Tested Product Current | Can Be Customized |
Maximum Test Capacity | Can Be Customized |
Working Time | Continuous Working Time Is 60min Under Full Power |
Quality Factor | 30~90 |
Input Working Power | Three-Phase 380V |
Ambient Temperature | -15~+40 |
Relative Humidity | Less Than 90rh%, No Condensation |
Altitude | <5000m |
Noise | Less Than 50dB |
Transport Package | Plywood Case with Foam and Waterproof Plastics |
Specification | Customized |
Trademark | EP Hipot |
Origin | Wuhan, China |
HS Code | 9030339000 |
Production Capacity | 500/Year |
Product Description
EP Hipot Electric Series Resonance AC Withstand tester high voltage Resonant test system for cableEPCZ Series Variable Frequency AC Resonance Test SystemEPCZ Series AC Resonance Test System is specially designed for AC withstand test for electric equipments of substation at 10kV~500kV or below. Applications:
- Transformer
- Cables
- GIS System
- Insulator
- CT/PT
- Generator
- Other electric devices
Features:
- Small size, portable for operating.
- Screen to show the test data, status and display operation step by real-time.
- Small temperature rising at rated load. Dry-type epoxy cast, high mechanical strength and good insulation ability.
- 220V or 380V single phase power source is suitable for on-site sourcing.
- Different type reactors for optional realize the multipurpose.
- With over current, over voltage, IPM and discharge protection function.
- Test result can be printed.
Rated output voltage: 0~500kV or belowOutput frequency: 20 -300Hz.Resonant voltage waveform: sine wave, waveform Distortion rate ≤ 1%.Full load working time: continuous working time 60mins.Quality factor: max. load ≥ 20.Frequency adjustment: fineness 0.1Hz, instability ≤ 0.01%.Power supply: 220V or 380V single-phase.Common Configuration:
Model | Test Object | Main Configurations: | |||
AC power source | Exciting Transformer | Reactor | Capacitive Voltage Divider: | ||
EPCZ-27/54/108-108Test Frequency: 20~300Hz | 31500kVA/35kV Power Transformer | 10KW 1 unit | 10KW 1 unit | 27kV/1A 4 UnitsFrequency: 20-300Hz | 120kV |
35kV circuit breaker, busbar, insulator | |||||
10kV(300mm2) cable 2000m | |||||
35kV(300mm2) cable 500m | |||||
EPCZ-54/108/216-216Test Frequency: 20~300Hz | 110kV Circuit breaker and busbar | 15kW 1 unit | 15kW 1 unit | 54kV/1A 4 UnitsFrequency: 20-300Hz | |
110kV GIS ≤ 10 intervals | |||||
35kV (300mm2) cable 1500m | |||||
10kV (300mm2) cable 3000m | |||||
110kV Full Insulated Transformer | |||||
EPCZ-65/130/260-520Test Frequency: 20~300Hz | 110kV Circuit Breaker and busbar | 30kW 1 Unit | 30kW 1 Unit | 65kV/2A 4 Units Frequency: 20-300Hz | 300kV |
110kV GIS ≤ 10 intervals | |||||
110kV (300mm2) cable 800m | |||||
35kV (300mm2) cable 3000m | |||||
10kV(300mm2) cable 200m | |||||
110kV Full Insulated Transformer | |||||
EPCZ-45/90/135/180/270-270Test Frequency: 20~300Hz | 110kV Insulator, switchgear, GIS and etc. | 20kW 1 unit | 20kW 1 unit | 45kV/1A Six UnitsFrequency: 20-300Hz | 200kV |
50MW/110kV Full Insulated Transformer | |||||
110kV (300mm2) cable 200m | |||||
35kV Power Transformer, switchgear, CT/PT, cable, etc. | |||||
20MW hydrogenator | |||||
10kV power transformer, switchgear, CT/PT, cables etc. | |||||
EPCZ18/36/54Test Frequency: 20~300Hz | 10kV (300mm2) cable 2000m | 5kW 1 Unit | 5kW 1 unit | 27kV/1A 2 units or18kV/1A 3 unitsFrequency: 20-300Hz | 60kV |
35kV (300mm2) cable 500m | |||||
10kV power transformer, switchgear, CT/PT etc. |
Note:
- Model EPCZ-27/54/108-108, EPCZ is the model of series, 27/54/108 is: voltage of one reactor (kV)/voltage of two reactors in series connection/voltage of four reactors in series connection. 108 is the total capacity (kVA).
- The test object is the common configuration for reference only. For details, please contact with us.
- If the capacity of your equipment is small and voltage is too low, can add more reactors to increase the capacity, and add more divider to increase the test voltage.